apache / apache/cloudstack

KVM: Hot-plugged NIC gets non-sequential PCI slot causing unpredictable interface naming in guest

Aperta
#12,825 1 commento 0 reazioni 0 assegnatari Vedi su GitHub
no-issue-activity type:improvement
Lingua principale
Java
Stelle
3.1k
Fork
1.4k
Merge medio
6g 19h
PR unite (30g)
32

Descrizione

## Description

When hot-plugging a NIC to a running KVM VM via CloudStack, the new NIC receives a non-sequential PCI slot address, resulting in unpredictable interface naming in the guest OS (e.g., `ens9` instead of the expected `ens5`). This causes guest network configuration to fail because CloudStack and cloud-init expect sequential interface naming.

## Root Cause

In `LibvirtPlugNicCommandWrapper.java`, the `execute()` method calls `vifDriver.plug()` which creates an `InterfaceDef` without setting a PCI slot (line 64). When `vm.attachDevice()` is called, libvirt auto-assigns the next free PCI slot. Since non-NIC PCI devices (virtio-serial controller, virtio-disk, memballoon, watchdog) occupy slots immediately after the existing NICs, the hot-plugged NIC gets a much higher slot number.

### Typical PCI slot layout for a CloudStack KVM VM:
| Slot | Device |
|------|--------|
| 0x01 | USB + IDE controllers |
| 0x02 | Video (cirrus) |
| 0x03 | NIC net0 → guest sees `ens3` |
| 0x04 | NIC net1 → guest sees `ens4` |
| 0x05 | virtio-serial controller |
| 0x06 | virtio-disk |
| 0x07 | memballoon |
| 0x08 | watchdog |
| 0x09 | **Hot-plugged NIC → guest sees `ens9` (should be `ens5`)** |

Note: `LibvirtReplugNicCommandWrapper` already handles this correctly by preserving the PCI slot when re-plugging (`interfaceDef.setSlot(oldPluggedNic.getSlot())`), but `LibvirtPlugNicCommandWrapper` has no slot assignment logic.

## Evidence (from production CloudStack 4.20)

**Before fix** — hot-plugged NIC at PCI slot 0x09:
```
$ virsh dumpxml i-2-1681-VM | grep -A6 'net2'

$ virsh qemu-agent-command i-2-1681-VM '{"execute":"guest-network-get-interfaces"}'
"name": "ens3", "hardware-address": "02:01:01:76:01:35"
"name": "ens4", "hardware-address": "02:01:03:15:00:01"
"name": "ens9", "hardware-address": "02:01:03:4c:00:08" ← non-sequential

$ ip a (inside guest):
4: ens9: mtu 1500 qdisc noop state DOWN
```

**After relocating non-NIC devices to high PCI slots (0x10+)** — hot-plugged NIC gets slot 0x04:
```
$ virsh qemu-agent-command i-2-1681-VM '{"execute":"guest-network-get-interfaces"}'
"name": "ens3", "hardware-address": "02:01:01:76:01:35"
"name": "ens4", "hardware-address": "02:aa:bb:cc:dd:01" ← sequential!
```

## Impact

- Hot-plugged NICs get `ens9`, `ens10`, etc. instead of sequential names
- Guest network configuration (cloud-init, CloudStack userdata) fails for the new NIC
- NIC shows as DOWN with no IP address in the guest
- Only a full VM reboot reassigns sequential PCI slots

## Fix

This PR adds explicit PCI slot assignment in `LibvirtPlugNicCommandWrapper`:
1. Query the domain XML to find all PCI slots currently in use
2. Find the highest PCI slot used by existing NICs
3. Assign the next free slot after the last NIC slot to the new NIC

**Note:** For full sequential naming, a follow-up change is needed to assign non-NIC PCI devices to higher slot numbers (e.g., 0x10+) during VM creation in `LibvirtComputingResource.createDevicesDef()`. This would leave slots 3-15 available for NICs, allowing hot-plugged NICs to always get sequential names.

## How to Reproduce

1. Create a KVM VM with 2 NICs
2. While running, add a 3rd NIC via CloudStack API/UI
3. Check inside guest: `ip link show` — the new NIC will be `ens9` (not `ens5`)
4. The NIC will be DOWN with no IP configuration

## Versions

- CloudStack 4.20
- QEMU 8.2, Libvirt 9.x
- Guest: Debian 12 (systemd-networkd with predictable interface naming)

Guida per i contributori

Apri la guida per i contributori

Direzione di ricerca

Leggere LibvirtPlugNicCommandWrapper.java, in particolare execute(), vifDriver.plug() e vm.attachDevice(), quindi confrontare la gestione degli slot in LibvirtReplugNicCommandWrapper. Il lavoro è completato quando il percorso di hot-plug assegna il successivo slot PCI disponibile dopo le NIC esistenti, in modo che il guest riceva una denominazione sequenziale delle interfacce; l’issue segnala inoltre un follow-up in LibvirtComputingResource.createDevicesDef().

Scritto dal modello di indicizzazione a partire dal testo della issue.

Valutazione

Stack tecnologico
java
Ambito
cloud, infrastructure
Tipo di issue
Bug
Difficoltà
3/5
Tempo stimato
1-2 giorni
Stato di attività
Ferma
Chiarezza
Specificata chiaramente
Idoneità per principianti
15/100

Ricevi le nuove issue nella tua casella