## Description

When hot-plugging a NIC to a running KVM VM via CloudStack, the new NIC receives a non-sequential PCI slot address, resulting in unpredictable interface naming in the guest OS (e.g., `ens9` instead of the expected `ens5`). This causes guest network configuration to fail because CloudStack and cloud-init expect sequential interface naming.

## Root Cause

In `LibvirtPlugNicCommandWrapper.java`, the `execute()` method calls `vifDriver.plug()` which creates an `InterfaceDef` without setting a PCI slot (line 64). When `vm.attachDevice()` is called, libvirt auto-assigns the next free PCI slot. Since non-NIC PCI devices (virtio-serial controller, virtio-disk, memballoon, watchdog) occupy slots immediately after the existing NICs, the hot-plugged NIC gets a much higher slot number.

### Typical PCI slot layout for a CloudStack KVM VM:
| Slot | Device |
|------|--------|
| 0x01 | USB + IDE controllers |
| 0x02 | Video (cirrus) |
| 0x03 | NIC net0 → guest sees `ens3` |
| 0x04 | NIC net1 → guest sees `ens4` |
| 0x05 | virtio-serial controller |
| 0x06 | virtio-disk |
| 0x07 | memballoon |
| 0x08 | watchdog |
| 0x09 | **Hot-plugged NIC → guest sees `ens9` (should be `ens5`)** |

Note: `LibvirtReplugNicCommandWrapper` already handles this correctly by preserving the PCI slot when re-plugging (`interfaceDef.setSlot(oldPluggedNic.getSlot())`), but `LibvirtPlugNicCommandWrapper` has no slot assignment logic.

## Evidence (from production CloudStack 4.20)

**Before fix** — hot-plugged NIC at PCI slot 0x09:
```
$ virsh dumpxml i-2-1681-VM | grep -A6 'net2'

$ virsh qemu-agent-command i-2-1681-VM '{"execute":"guest-network-get-interfaces"}'
"name": "ens3", "hardware-address": "02:01:01:76:01:35"
"name": "ens4", "hardware-address": "02:01:03:15:00:01"
"name": "ens9", "hardware-address": "02:01:03:4c:00:08" ← non-sequential

$ ip a (inside guest):
4: ens9: mtu 1500 qdisc noop state DOWN
```

**After relocating non-NIC devices to high PCI slots (0x10+)** — hot-plugged NIC gets slot 0x04:
```
$ virsh qemu-agent-command i-2-1681-VM '{"execute":"guest-network-get-interfaces"}'
"name": "ens3", "hardware-address": "02:01:01:76:01:35"
"name": "ens4", "hardware-address": "02:aa:bb:cc:dd:01" ← sequential!
```

## Impact

- Hot-plugged NICs get `ens9`, `ens10`, etc. instead of sequential names
- Guest network configuration (cloud-init, CloudStack userdata) fails for the new NIC
- NIC shows as DOWN with no IP address in the guest
- Only a full VM reboot reassigns sequential PCI slots

## Fix

This PR adds explicit PCI slot assignment in `LibvirtPlugNicCommandWrapper`:
1. Query the domain XML to find all PCI slots currently in use
2. Find the highest PCI slot used by existing NICs
3. Assign the next free slot after the last NIC slot to the new NIC

**Note:** For full sequential naming, a follow-up change is needed to assign non-NIC PCI devices to higher slot numbers (e.g., 0x10+) during VM creation in `LibvirtComputingResource.createDevicesDef()`. This would leave slots 3-15 available for NICs, allowing hot-plugged NICs to always get sequential names.

## How to Reproduce

1. Create a KVM VM with 2 NICs
2. While running, add a 3rd NIC via CloudStack API/UI
3. Check inside guest: `ip link show` — the new NIC will be `ens9` (not `ens5`)
4. The NIC will be DOWN with no IP configuration

## Versions

- CloudStack 4.20
- QEMU 8.2, Libvirt 9.x
- Guest: Debian 12 (systemd-networkd with predictable interface naming)

Beitragsleitfaden

Beitragsleitfaden öffnen

Rechercherichtung

Lesen Sie LibvirtPlugNicCommandWrapper.java, insbesondere execute(), vifDriver.plug() und vm.attachDevice(), und vergleichen Sie anschließend die Slot-Behandlung in LibvirtReplugNicCommandWrapper. Erledigt ist die Aufgabe, wenn der Hot-Plug-Pfad den nächsten verfügbaren PCI-Slot nach den vorhandenen NICs zuweist, sodass der Gast eine sequenzielle Benennung der Schnittstellen erhält; das Issue erwähnt außerdem ein Follow-up in LibvirtComputingResource.createDevicesDef().

Vom Indexierungsmodell aus dem Issue-Text verfasst.

Bewertung

Tech-Stack
java
Bereich
cloud, infrastructure
Issue-Typ
Bug
Schwierigkeit
3/5
Geschätzter Aufwand
1-2 Tage
Aktivitätsstatus
Veraltet
Klarheit
Klar beschrieben
Anfängerfreundlichkeit
15/100

Neue Issues direkt in Ihr Postfach

Eine kurze Übersicht über anfängerfreundliche GitHub-Issues.