apache / apache/cloudstack

KVM: Hot-plugged NIC gets non-sequential PCI slot causing unpredictable interface naming in guest

Abierto
#12,825 1 comentario 0 reacciones 0 asignados Ver en GitHub
no-issue-activity type:improvement
Lenguaje dominante
Java
Estrellas
3.1k
Forks
1.4k
Merge medio
6 d 19 h
PR fusionados (30 d)
32

Descripción

## Description

When hot-plugging a NIC to a running KVM VM via CloudStack, the new NIC receives a non-sequential PCI slot address, resulting in unpredictable interface naming in the guest OS (e.g., `ens9` instead of the expected `ens5`). This causes guest network configuration to fail because CloudStack and cloud-init expect sequential interface naming.

## Root Cause

In `LibvirtPlugNicCommandWrapper.java`, the `execute()` method calls `vifDriver.plug()` which creates an `InterfaceDef` without setting a PCI slot (line 64). When `vm.attachDevice()` is called, libvirt auto-assigns the next free PCI slot. Since non-NIC PCI devices (virtio-serial controller, virtio-disk, memballoon, watchdog) occupy slots immediately after the existing NICs, the hot-plugged NIC gets a much higher slot number.

### Typical PCI slot layout for a CloudStack KVM VM:
| Slot | Device |
|------|--------|
| 0x01 | USB + IDE controllers |
| 0x02 | Video (cirrus) |
| 0x03 | NIC net0 → guest sees `ens3` |
| 0x04 | NIC net1 → guest sees `ens4` |
| 0x05 | virtio-serial controller |
| 0x06 | virtio-disk |
| 0x07 | memballoon |
| 0x08 | watchdog |
| 0x09 | **Hot-plugged NIC → guest sees `ens9` (should be `ens5`)** |

Note: `LibvirtReplugNicCommandWrapper` already handles this correctly by preserving the PCI slot when re-plugging (`interfaceDef.setSlot(oldPluggedNic.getSlot())`), but `LibvirtPlugNicCommandWrapper` has no slot assignment logic.

## Evidence (from production CloudStack 4.20)

**Before fix** — hot-plugged NIC at PCI slot 0x09:
```
$ virsh dumpxml i-2-1681-VM | grep -A6 'net2'

$ virsh qemu-agent-command i-2-1681-VM '{"execute":"guest-network-get-interfaces"}'
"name": "ens3", "hardware-address": "02:01:01:76:01:35"
"name": "ens4", "hardware-address": "02:01:03:15:00:01"
"name": "ens9", "hardware-address": "02:01:03:4c:00:08" ← non-sequential

$ ip a (inside guest):
4: ens9: mtu 1500 qdisc noop state DOWN
```

**After relocating non-NIC devices to high PCI slots (0x10+)** — hot-plugged NIC gets slot 0x04:
```
$ virsh qemu-agent-command i-2-1681-VM '{"execute":"guest-network-get-interfaces"}'
"name": "ens3", "hardware-address": "02:01:01:76:01:35"
"name": "ens4", "hardware-address": "02:aa:bb:cc:dd:01" ← sequential!
```

## Impact

- Hot-plugged NICs get `ens9`, `ens10`, etc. instead of sequential names
- Guest network configuration (cloud-init, CloudStack userdata) fails for the new NIC
- NIC shows as DOWN with no IP address in the guest
- Only a full VM reboot reassigns sequential PCI slots

## Fix

This PR adds explicit PCI slot assignment in `LibvirtPlugNicCommandWrapper`:
1. Query the domain XML to find all PCI slots currently in use
2. Find the highest PCI slot used by existing NICs
3. Assign the next free slot after the last NIC slot to the new NIC

**Note:** For full sequential naming, a follow-up change is needed to assign non-NIC PCI devices to higher slot numbers (e.g., 0x10+) during VM creation in `LibvirtComputingResource.createDevicesDef()`. This would leave slots 3-15 available for NICs, allowing hot-plugged NICs to always get sequential names.

## How to Reproduce

1. Create a KVM VM with 2 NICs
2. While running, add a 3rd NIC via CloudStack API/UI
3. Check inside guest: `ip link show` — the new NIC will be `ens9` (not `ens5`)
4. The NIC will be DOWN with no IP configuration

## Versions

- CloudStack 4.20
- QEMU 8.2, Libvirt 9.x
- Guest: Debian 12 (systemd-networkd with predictable interface naming)

Guía de contribución

Abrir la guía de contribución

Línea de trabajo

Lea LibvirtPlugNicCommandWrapper.java, especialmente execute(), vifDriver.plug() y vm.attachDevice(), y compare después el manejo de slots en LibvirtReplugNicCommandWrapper. Se considera completado cuando la ruta de hot-plug asigna el siguiente slot PCI disponible después de las NIC existentes, de modo que el guest reciba nombres de interfaz secuenciales; el issue también señala un follow-up en LibvirtComputingResource.createDevicesDef().

Escrito por el modelo de indexación a partir del texto del issue.

Evaluación

Stack tecnológico
java
Área
cloud, infrastructure
Tipo de issue
Error
Dificultad
3/5
Tiempo estimado
1-2 días
Estado de actividad
Estancado
Claridad
Bien especificado
Aptitud para principiantes
15/100

Recibe los nuevos issues en tu correo

Un resumen breve de issues de GitHub para principiantes.