[V8 perf] Loop callback changing is throttling
Nadie ha tomado este issue todavía.
- Lenguaje dominante
- JavaScript
- Estrellas
- 122k
- Forks
- 37.3k
- Merge medio
- 4 d 2 h
- PR fusionados (30 d)
- 283
Descripción
Version
v24.20.0
Platform
Windows 10
Subsystem
No response
What steps will reproduce the bug?
- Clone the repo https://github.com/AlttiRi/loop-callback-throttling-bug
- Install deps (
"sharp") - Run
demo-1.tsanddemo-2.ts
How often does it reproduce? Is there a required condition?
Always
What is the expected behavior? Why is that the expected behavior?
- BOX (~5 secs) ✅
- BOX (~5 secs) ✅
- LANCZOS (~8 secs) ✅
- LANCZOS (~8 secs) ✅
What do you see instead?
- BOX (~5 secs) ✅
- BOX (~5 secs) ✅
- LANCZOS (~30 secs) ❌
- LANCZOS (~30 secs) ❌
Additional information
I have downsample1D_V1 function (it's very unoptimized, but it works, and it's perfect for the demonstration), which executes the passed callback const weight = fn(x); billions of times (3_107_687_040 times per 1 downsample2D call).
There are 2 types of the passed callback function — lanczos3 and box:
function lanczos3(x: number): number {
if (-3 <= x && x < 3) {
return sinc(x) * sinc(x / 3);
}
return 0;
}
function sinc(x: number): number {
if (x === 0) {
return 1;
}
x = Math.PI * x;
return Math.sin(x) / x;
}
function box(x: number): number {
if (x > -0.5 && x <= 0.5) {
return 1;
}
return 0;
}
I call downsample2D multiple times with the follow callback params (demo-1.ts):
- BOX (~5 secs) ✅
- BOX (~5 secs) ✅
- LANCZOS (~30 secs) ❌
- LANCZOS (~30 secs) ❌
The first 2 calls work with the expected speed, for ~5 second.
But when the callback is changed, downsample2D works multiple times slower than expected, for ~30 seconds.
In reverse order I also face the throttling (demo-2.ts):
- LANCZOS (~8 secs) ✅
- LANCZOS (~8 secs) ✅
- BOX (~30 secs) ❌
- BOX (~30 secs) ❌
The problem appears on both Node.js (24) and Deno (2.9).
Bun (1.3/1.4) works fine:
- BOX (~5 secs) ✅
- BOX (~5 secs) ✅
- LANCZOS (~8 secs) ✅
- LANCZOS (~8 secs) ✅
Related keywords: performance v8 polymorphic inline cache
Guía de contribución
Primeros pasos
- Lee el issue completo y luego la guía de contribución del proyecto.
- Comenta en el issue que vas a ocuparte — evita que dos personas hagan lo mismo.
- Haz un fork del repositorio y trabaja en una rama.
- Abre un pull request que haga referencia al número del issue.
Línea de trabajo
Empieza clonando la reproducción enlazada y ejecutando demo-1.ts y demo-2.ts con Node.js v24, comparando los tiempos al cambiar los callbacks. Investiga el comportamiento reportado de la caché inline polimórfica de V8 y verifica el resultado con los casos BOX y LANCZOS. Se considera terminado cuando cambiar los callbacks ya no hace que las llamadas repetidas a downsample2D se ralenticen con respecto a los tiempos esperados.
Escrito por el modelo de indexación a partir del texto del issue.
Evaluación
- Stack tecnológico
- javascript
- Área
- performance
- Tipo de issue
- Error
- Dificultad
- 5/5
- Tiempo estimado
- Más de una semana
- Estado de actividad
- Activo
- Claridad
- Necesita aclaración
- Aptitud para principiantes
- 25/100