SIGINT exits prompt process but model work continues and OTel later reports success
まだ誰も着手していません。
- 主要言語
- Shell
- スター
- 11.2k
- フォーク
- 1.9k
- 平均マージ
- 14時間 16分
- マージ済み PR(30日)
- 6
説明
Describe the bug
Interrupting an active non-interactive model call with SIGINT exits the foreground Copilot process, but a descendant/native worker continues producing output and completing the model call. The OTel file appears much later and records the interrupted operation as a successful completion rather than cancelled.
This means cancellation is not promptly propagated to the underlying work and can continue consuming model resources after the foreground process has exited.
Affected version
GitHub Copilot CLI 1.0.83 on macOS.
Steps to reproduce
- Enable the OTel file exporter and force content capture off.
- Run
copilot --prompt ... --stream on --model <available-model> --output-format jsonwith a synthetic prompt that produces a long response; redirect output to a file. - Wait for
model.call_startand send SIGINT before the firstassistant.message_delta. - Record foreground process exit, then continue observing the output and telemetry paths.
Observed result
- SIGINT was sent with zero response deltas observed.
- The foreground process returned as terminated by SIGINT.
- Approximately 55 seconds after the foreground process had exited, inherited output continued to grow and the telemetry file appeared.
- Output contained partial response deltas but no
model.call_finishedorassistant.turn_endrecord. - OTel nevertheless contained a completed
chatspan and rootinvoke_agentspan with status code 0, finish reasonstop, response model, and full token usage. No cancellation/error attribute was present.
A prior late-stream attempt showed the same delayed-file behavior but was not suitable for proving when cancellation was sent. The reproduction above signals immediately after model.call_start.
Expected behavior
On the first termination signal, Copilot should propagate cancellation to child/native inference work, end active spans with a cancelled/error outcome, force-flush and shut down exporters with a bounded timeout, and then preserve the conventional signal exit result. No model work or output writer should remain active after the foreground command reports termination.
A downstream Collector cannot correct a successful producer span or cancel orphaned producer work.
Privacy
The reproduction used only synthetic content and OTEL_INSTRUMENTATION_GENAI_CAPTURE_MESSAGE_CONTENT=false. No credentials or user data are included.
コントリビューションガイド
はじめの一歩
- issue を最後まで読み、次にプロジェクトのコントリビューションガイドを読みます。
- 着手することを issue にコメントします — 二人が同じ作業をするのを防げます。
- リポジトリをフォークし、ブランチを切って変更します。
- issue 番号を参照したプルリクエストを送ります。
調査の方向性
SIGINT の処理から子プロセス/ネイティブ推論処理、OTel ファイル exporter まで、非対話型の --prompt パスを追跡します。最初の delta より前にシグナルが発生するシナリオを再現し、その後、キャンセルによって子孫の処理が停止すること、アクティブな span がキャンセルまたはエラーの結果で終了すること、exporter が上限時間内に flush すること、終了後に出力 writer が残らないことを検証します。
索引モデルが issue の本文から書いたものです。
評価
- 技術スタック
- shell
- 領域
- cli, observability-sre
- issue の種類
- バグ
- 難易度
- 4/5
- 見積もり時間
- 3〜5日
- 活発さ
- 活発
- 明瞭さ
- おおむね明確
- 初心者へのやさしさ
- 45/100