### problem

Hi all.

In our PoC installation, I configured two disk offerings with different IOPs limits (1,000 and 10,000).
When I launch a test VM, the limit is applied correctly.
```xml


10000
10000

```
While the VM is running, I can change the offering, and a success message is displayed. Everything also looks successful in the management-server.log.
```
2026-05-19 16:31:47,618 DEBUG [o.a.c.f.j.i.AsyncJobManagerImpl] (API-Job-Executor-58:[ctx-e71e416f, job-1276, ctx-ee83f22a]) (logid:2c9eb69a) Complete async job-1276, jobStatus: SUCCEEDED, resultCode: 0, result: org.apache.cloudstack.api.response.VolumeResponse/volume/{"id":"d8a513c5-6241-46a9-b0d8-f969a5a245ce","name":"ROOT-61","zoneid":"57a96360-8053-487c-9fb9-85af87ca697d","zonename":"lc01","type":"ROOT","deviceid":"0","virtualmachineid":"e90057c4-5be9-492e-a78f-dfbca7507e07","templateid":"4c6bfba7-2457-466e-8767-7b3e620bb4e5","templatename":"Win2025-test2","templatedisplaytext":"Win2025-test2","vmname":"test-win02","vmdisplayname":"test-win02","vmstate":"Running","vmtype":"User","provisioningtype":"thin","size":"(50.00 GB) 53687091200","created":"2026-05-18T13:21:38+0200","state":"Ready","account":"admin","domainid":"b6a1560b-2912-11f1-af58-0050560103cb","domain":"ROOT","domainpath":"ROOT","diskIopsReadRate":"1000","diskIopsWriteRate":"1000","diskkbsread":"(1.33 MB) 1394345","diskkbswrite":"(43.25 KB) 44290","diskioread":"(52.04 KB) 53286","diskiowrite":"(3.00 KB) 3076","diskofferingid":"1b621070-6092-4d6e-91e1-987e662f2dd1","diskofferingname":"disk-1000","diskofferingdisplaytext":"disk-1000","destroyed":"false","isextractable":"false","displayvolume":"true","quiescevm":"false","supportsstoragesnapshot":"false","deleteprotection":"false","tags":[],"hasannotations":"false"}
```
However, the configuration of the VM on the KVM host remains the same.
```xml


10000
10000

```
The limit is only applied if I completely power down the VM and then power it back on.
Is there a trick to this, or something I've missed?

### versions

ACS 4.22.0
KVM/Qemu on Ubuntu 24.04

### The steps to reproduce the bug

1.
2.
3.
...

### What to do about it?

_No response_

Hướng dẫn đóng góp

Mở hướng dẫn đóng góp

Hướng nghiên cứu

Tái hiện sự cố trên ACS 4.22.0 với KVM/QEMU trên Ubuntu 24.04, bằng cách chuyển một VM đang chạy giữa các Disk Offering có giới hạn IOPS khác nhau. So sánh kết quả trong management-server.log với XML trực tiếp của VM trước và sau khi thay đổi; hoàn tất khi các giá trị iotune của VM đang chạy thay đổi mà không cần tắt VM.

Do mô hình lập chỉ mục viết ra từ nội dung của issue.

Đánh giá

Công nghệ
java
Lĩnh vực
cloud, infrastructure
Loại issue
Lỗi
Độ khó
4/5
Thời gian dự kiến
3-5 ngày
Mức độ hoạt động
Sôi nổi
Độ rõ ràng
Cần làm rõ
Mức phù hợp với người mới
38/100

Nhận issue mới trong hộp thư của bạn

Bản tóm tắt ngắn những issue GitHub phù hợp với người mới.