Unity-Technologies / Unity-Technologies/com.unity.netcode.gameobjects
RPC send/receive logging as an additional verbose logging level for developer debugging
Nessuno ha ancora preso questa issue.
- Lingua principale
- C#
- Stelle
- 2.3k
- Fork
- 461
- Merge medio
- 3g 16h
- PR unite (30g)
- 20
Descrizione
It's excellent that RPCs appear in the Profiler. However, sometimes it's still nice to have logging of your RPCs that are being sent or received. You could include this in LogLevel.Developer or have a new LogLevel.Verbose
In RpcMessage.cs I would modify Deserialize:
public static unsafe bool Deserialize(ref FastBufferReader reader, ref NetworkContext context, ref RpcMetadata metadata, ref FastBufferReader payload)
{
ByteUnpacker.ReadValueBitPacked(reader, out metadata.NetworkObjectId);
ByteUnpacker.ReadValueBitPacked(reader, out metadata.NetworkBehaviourId);
ByteUnpacker.ReadValueBitPacked(reader, out metadata.NetworkRpcMethodId);
var networkManager = (NetworkManager)context.SystemOwner;
if (!networkManager.SpawnManager.SpawnedObjects.ContainsKey(metadata.NetworkObjectId))
{
networkManager.DeferredMessageManager.DeferMessage(IDeferredNetworkMessageManager.TriggerType.OnSpawn, metadata.NetworkObjectId, reader, ref context);
return false;
}
var networkObject = networkManager.SpawnManager.SpawnedObjects[metadata.NetworkObjectId];
var networkBehaviour = networkManager.SpawnManager.SpawnedObjects[metadata.NetworkObjectId].GetNetworkBehaviourAtOrderIndex(metadata.NetworkBehaviourId);
if (networkBehaviour == null)
{
return false;
}
if (!NetworkManager.__rpc_func_table.ContainsKey(metadata.NetworkRpcMethodId))
{
return false;
}
payload = new FastBufferReader(reader.GetUnsafePtrAtCurrentPosition(), Allocator.None, reader.Length - reader.Position);
#if DEVELOPMENT_BUILD || UNITY_EDITOR
if (NetworkManager.__rpc_name_table.TryGetValue(metadata.NetworkRpcMethodId, out var rpcMethodName))
{
if (NetworkLog.CurrentLogLevel == LogLevel.Developer) NetworkLog.LogInfo("RPC Received: " + rpcMethodName);
networkManager.NetworkMetrics.TrackRpcReceived(
context.SenderId,
networkObject,
rpcMethodName,
networkBehaviour.__getTypeName(),
reader.Length);
}
#endif
return true;
}
And in NetworkBehaviour.cs I would modify __beginSendServerRpc and __beginSendClientRpc:
#pragma warning disable IDE1006 // disable naming rule violation check
// RuntimeAccessModifiersILPP will make this `protected`
internal FastBufferWriter __beginSendServerRpc(uint rpcMethodId, ServerRpcParams serverRpcParams, RpcDelivery rpcDelivery)
#pragma warning restore IDE1006 // restore naming rule violation check
{
#if DEVELOPMENT_BUILD || UNITY_EDITOR
if (NetworkManager.__rpc_name_table.TryGetValue(rpcMethodId, out var rpcMethodName))
{
if (NetworkLog.CurrentLogLevel == LogLevel.Developer) NetworkLog.LogInfo("RPC Sent " + rpcMethodName);
}
#endif
return new FastBufferWriter(k_RpcMessageDefaultSize, Allocator.Temp, k_RpcMessageMaximumSize);
}
#pragma warning disable IDE1006 // disable naming rule violation check
// RuntimeAccessModifiersILPP will make this `protected`
internal FastBufferWriter __beginSendClientRpc(uint rpcMethodId, ClientRpcParams clientRpcParams, RpcDelivery rpcDelivery)
#pragma warning restore IDE1006 // restore naming rule violation check
{
#if DEVELOPMENT_BUILD || UNITY_EDITOR
if (NetworkManager.__rpc_name_table.TryGetValue(rpcMethodId, out var rpcMethodName))
{
if (NetworkLog.CurrentLogLevel == LogLevel.Developer) NetworkLog.LogInfo("RPC Sent " + rpcMethodName);
}
#endif
return new FastBufferWriter(k_RpcMessageDefaultSize, Allocator.Temp, k_RpcMessageMaximumSize);
}
Guida per i contributori
Apri la guida per i contributori
Come iniziare
- Leggi tutta la issue e poi la guida ai contributi del progetto.
- Commenta sulla issue per dire che te ne occupi tu — evita che due persone facciano lo stesso lavoro.
- Fai un fork del repository e lavora su un branch.
- Apri una pull request che faccia riferimento al numero della issue.
Direzione di ricerca
Inizia esaminando RpcMessage.cs Deserialize e NetworkBehaviour.cs __beginSendServerRpc e __beginSendClientRpc, insieme al comportamento esistente di LogLevel e NetworkLog. Decidi se i messaggi di invio/ricezione RPC appartengono a LogLevel.Developer o richiedono un nuovo livello dettagliato, quindi verifica che entrambe le direzioni registrino il nome dell'RPC senza modificare il comportamento del profiler o delle metriche.
Scritto dal modello di indicizzazione a partire dal testo della issue.
Valutazione
- Stack tecnologico
- csharp, unity
- Ambito
- networking
- Tipo di issue
- Funzionalità
- Difficoltà
- 3/5
- Tempo stimato
- 1-2 giorni
- Stato di attività
- Ferma
- Chiarezza
- Abbastanza chiara
- Idoneità per principianti
- 35/100