説明
## Where?
/ibex_gui
The issue appears to be caused by the default value of the 'Muon Cerenkov Pulse' radio button being set to 'First' so selecting 'Second' and switching instruments without appying changes, and switch back results as both 'First' and 'Second' buttons being selected.
## Reproducible?
Yes
### To Reproduce
From LocalHost, select the 'DAE' -> 'Experiment Setup' -> 'Data acquisition'. Select the 'Second' button within the 'Muon Cerenkov Pulse' button selection. Switch to another instrument i.e. 'DEMO' and then switch back to your local instrument, the 'Muon Cerenkov Pulse' radio buttons will both be selected:

## Acceptance criteria
- [ ] Switching between instruments does no result in both buttons being selected