python / python/cpython

Limit the reading size from Unix sockets to avoid memory overallocation

Abierto
#123,557 0 comentarios 0 reacciones 0 asignados Ver en GitHub

Nadie ha tomado este issue todavía.

stdlib type-feature
Lenguaje dominante
Python
Estrellas
77.2k
Forks
35.9k
Métricas de merge de PR
Métricas de PR pendientes

Descripción

Feature or enhancement

Proposal:

This issue is strongly related to the following issue, where code was merged to limit the reading size of pipes to avoid memory overallocation and runtime slowdowns: https://github.com/python/cpython/issues/121313

import multiprocessing
import os

def sender(pipe, data):
    pipe.send(data)
    pipe.close()

def receiver(pipe):
    r = pipe.recv()
    print(f"Received data size: {len(r)} Bytes")

socket1, socket2 = multiprocessing.Pipe()

data = 'a' * (512**3)  

p1 = multiprocessing.Process(target=sender, args=(socket2, data))
p2 = multiprocessing.Process(target=receiver, args=(socket1,))

p1.start()
p2.start()

p1.join()
p2.join()
print("Transfer complete.")

Consider the simple Python script above, that creates a supposed pipe using multiprocessing.Pipe() between two processes so that one process can send data to the other. One would suppose that a Unix pipe is created, but that is not the case.

multiprocessing.Pipe()by default creates what the documentation describes as a bidirectional pipe, which, when having a closer look at the actual multiprocessing source code, is a pair of Unix sockets.

When reading from such a Unix socket, the same behavior as when reading from a pipe can be observed: The _recv() function is called with the total remaining amount of data that needs to be read, and that parameter is passed down to the os_read_impl(), which results in the allocation of a huge VMA, installation of a PMD-sized THP, resizing and finally unmapping of the VMA. Since the problem is nearly identical for sockets as it is for pipes, I've slightly extended the previously merged pipe solution to mitigate this problem as well:

        is_pipe = is_socket = False
        if size > self._default_pipe_size > 0:
            mode = os.fstat(handle).st_mode
            is_pipe = stat.S_ISFIFO(mode)
            is_socket = stat.S_ISSOCK(mode)
        limit = self._default_pipe_size if is_pipe or is_socket else remaining

The only difference between using pipes or sockets is the amount of data returned by the read() system call. Unlike pipes having a default limit of 64 KiB,strace shows that Unix sockets can, by default, transfer around 200 KiB-300 KiB per read().

It is important to note that on Linux the default socket size can be printed by checking the /proc/sys/net/core/(r/w)mem_default}. This value is not really relevant since, due to process interleaving, reading more data is possible.

Furthermore, although it is possible to read 200 KiB-300 KiB, testing has shown that using the same limit as the pipe buffer solution --> 64 KiB on systems with 4 KiB base pages, results in the best performance.

Here's some performance numbers: Without the patch the runtime of above code snippet is approx. 0.234s, and with the patch approx. 0.135s, resulting in a speedup of 1.7x.

I've done some testing with larger limits closer to the actual read size of a Unix socket, like 250 KiB. The problem, thereby, is that although no new VMA is created for the above code, meaning the data is put onto the default heap, the heap top is constantly shifted since the input buffers are deleted after each reading round.

Has this already been discussed elsewhere?

I have already discussed this feature proposal on Discourse

Links to previous discussion of this feature:

https://discuss.python.org/t/request-for-review-of-gh-121313-limit-the-reading-size-from-pipes-to-their-default-buffer-size-on-unix-systems/62389/3

Linked PRs
  • gh-123558

Guía de contribución

Abrir la guía de contribución

Primeros pasos

  1. Lee el issue completo y luego la guía de contribución del proyecto.
  2. Comenta en el issue que vas a ocuparte — evita que dos personas hagan lo mismo.
  3. Haz un fork del repositorio y trabaja en una rama.
  4. Abre un pull request que haga referencia al número del issue.

Línea de trabajo

Comienza con multiprocessing.Pipe(), la función _recv() y os_read_impl(), y después compara el cambio de tamaño de pipe enlazado en el issue 121313 y el PR 123558. Se considera completado cuando las lecturas de Unix-socket están limitadas sin cambiar ningún otro comportamiento de lectura, y se mantienen las mejoras de memoria y rendimiento indicadas.

Escrito por el modelo de indexación a partir del texto del issue.

Evaluación

Stack tecnológico
python
Área
operating-systems
Tipo de issue
Nueva funcionalidad
Dificultad
4/5
Tiempo estimado
3-5 días
Estado de actividad
Estancado
Claridad
Bastante claro
Aptitud para principiantes
35/100

Recibe los nuevos issues en tu correo

Un resumen breve de issues de GitHub para principiantes.