optimizely / optimizely/java-sdk

[BUG] If configuration file initialization fails, the configuration file remains uninitialized indefinitely

Aperta
#574 0 commenti 0 reazioni 0 assegnatari Vedi su GitHub

Nessuno ha ancora preso questa issue.

bug
Lingua principale
Java
Stelle
44
Fork
32
Merge medio
8h 39m
PR unite (30g)
1

Descrizione

Is there an existing issue for this?
  • I have searched the existing issues
SDK Version

3.2.0-alpha to 4.2.2.
Since this commit: Update HttpProjectConfigManager to use Last-Modified time (https://github.com/optimizely/java-sdk/pull/292)

Current Behavior

If the initialization of the configuration file fails, the configuration file remains un-initilialized indefinitely until the server/pod is restarted, or the configuration gets updated on Optimizely platform.

Expected Behavior

If the configuration file cannot be initialized at server start-up (eg: because Optimizely is down or takes to much time to respond), then during the next configuration poll, the configuration should be updated, even if Optimizely returns an HTTP 304 (Not Modified) code.

Steps To Reproduce
  • At initialization of the PollingProjectConfigManager the connection is broken, or there is a time out, or an error. => PollingProjectConfigManager.currentProjectConfig is empty.
  • 5min later, PollingProjectConfigManager.poll() polls the config file, but receives HTTP 304 from Optimizely => PollingProjectConfigManager.currentProjectConfig remains empty.
  • 5min later, still no modification on the configuration => PollingProjectConfigManager.currentProjectConfig remains empty.
  • PollingProjectConfigManager.currentProjectConfig is never initialized (except if a modification on the configuration is done on Optimizely side, or the server is restarted).
Java Version

No response

Link

No response

Logs

No response

Severity

Affecting users

Workaround/Solution

See the HttpProjectConfigManager:
https://github.com/optimizely/java-sdk/blob/746e81530a9224fabcd7f610d81800358e6e34c9/core-httpclient-impl/src/main/java/com/optimizely/ab/config/HttpProjectConfigManager.java#L95-L121

Here, the condition handling the HttpStatus.SC_NOT_MODIFIED should check if the currentProjectConfig is initialized or not. If it is empty, it means the configuration file has never been initialized properly and the configuration should thus be returned.

Recent Change

No response

Conflicts

No response

Guida per i contributori

Apri la guida per i contributori

Come iniziare

  1. Leggi tutta la issue e poi la guida ai contributi del progetto.
  2. Commenta sulla issue per dire che te ne occupi tu — evita che due persone facciano lo stesso lavoro.
  3. Fai un fork del repository e lavora su un branch.
  4. Apri una pull request che faccia riferimento al numero della issue.

Direzione di ricerca

Inizia da core-httpclient-impl/src/main/java/com/optimizely/ab/config/HttpProjectConfigManager.java, in particolare dalla gestione di HttpStatus.SC_NOT_MODIFIED intorno alle righe 95–121. Traccia il modo in cui PollingProjectConfigManager inizializza e interroga currentProjectConfig dopo un HTTP 304. Il lavoro è completato quando un avvio non riuscito può inizializzare la configurazione durante un polling successivo anche quando la risposta è 304.

Scritto dal modello di indicizzazione a partire dal testo della issue.

Valutazione

Stack tecnologico
java
Ambito
backend
Tipo di issue
Bug
Difficoltà
2/5
Tempo stimato
1-3 ore
Stato di attività
Ferma
Chiarezza
Specificata chiaramente
Idoneità per principianti
55/100

Ricevi le nuove issue nella tua casella

Un breve riepilogo di issue GitHub adatte ai principianti.