hardbyte / hardbyte/python-can

error using multiple Vector devices

未关闭
#971 1 条评论 0 个 reaction 已指派 0 人 在 GitHub 查看
主要语言
Python
星标
1.6k
派生
697
PR 合并指标
30 天内没有已合并 PR

描述

The setup contains 2 Vector devices and a CAN cable that connects the ECU and the 2 boxes (using the first piggy on each device):
* Vector Vn1630A
* Vector VH6501

``CANoe CAN1`` is assigned to the first piggy of the VH6501 device.

If I assign ``MyAPP CAN1`` to the same piggy then I can record the traffic.
If I assign ``MyAPP CAN1`` to the first piggy of VN1630A then I get the following error:

```
Details: Traceback (most recent call last):
File "MyAPP\xil\devices\can_device.py", line 276, in prepare
File "lib\site-packages\can\util.py", line 303, in wrapper
File "lib\site-packages\can\interfaces\vector\canlib.py", line 183, in __init__
File "lib\site-packages\can\interfaces\vector\canlib.py", line 686, in get_application_config
File "lib\site-packages\can\interfaces\vector\xldriver.py", line 35, in check_status
can.interfaces.vector.exceptions.VectorError: xlGetApplConfig failed (XL_ERROR)
```

Any idea about what is going on here?