apache / apache/servicecomb-java-chassis
INFO Required: Edge gateway service routing to mesher Side car proxy
- Vorherrschende Sprache
- Java
- Sterne
- 1.9k
- Forks
- 814
- Ø Merge
- 8 T. 23 Std.
- Gemergte PRs (30 T.)
- 1
Beschreibung
Below is the system flow i am experimenting with,
====================================
Edge service ( developed with java chassis SDK) <-> Side car Proxy connector (built with Service-mesh and service ports configured to point to legacy application) --> Legacy Servlet application
====================================================
I can successfully able to run mesher as side car proxy and get it registered in the service center. I can also able to hit provider API's (servlet based application) via mesher side car proxy.
However I can't able to route to the provider application via mesher side car proxy from the edge gateway.
Below is the routing configuration in edge service.
* I am using `URLMappedEdgeDispatcher`.
* And `legacy` is name of the side car provider mesher microservice with which it has been registered in the service center.
``` http:
dispatcher:
edge:
url:
enabled: true
mappings:
legacy:
path: "/legacy/.*"
microserviceName: legacy
prefixSegmentCount: 0
versionRule: 0.0.0+ `
```
I am getting this error on runtime
```
**2022-11-10 17:38:46,606 [ERROR] [transport-vert.x-eventloop-thread-3] - locate path failed, status:Not Found, http method:GET, path:/calculator/bmi/, microserviceName:calculator (OperationLocator.java:72)**
```
@liubao68 It seems URLMappedEdgeDispatcher is not the right one to use here as it does schema based routing. Please help point me how we can achieve this? are there any other dispatchers which would effectively route traffic from edge service to side car proxy mesher connector?
Beitragsleitfaden
Für dieses Repository ist kein Beitragsleitfaden indexiert
Rechercherichtung
Beginne mit URLMappedEdgeDispatcher und der gezeigten Edge-Routing-Konfiguration und verfolge dann den OperationLocator-Fehler für /calculator/bmi/ und microserviceName calculator. Stelle den Routing-Ablauf von der Edge zu Mesher nach und vergleiche ihn mit dem erfolgreich registrierten Legacy-Sidecar-Pfad. Als abgeschlossen gilt die Aufgabe, wenn das Edge-Gateway Anfragen über den Mesher-Sidecar an den Legacy-Provider weiterleitet.
Vom Indexierungsmodell aus dem Issue-Text verfasst.
Bewertung
- Tech-Stack
- java
- Bereich
- backend, networking
- Issue-Typ
- Bug
- Schwierigkeit
- 4/5
- Geschätzter Aufwand
- 3-5 Tage
- Aktivitätsstatus
- Veraltet
- Klarheit
- Muss geklärt werden
- Anfängerfreundlichkeit
- 25/100