### Describe the bug

When a buffer has `writerIndex == 0` (e.g., a string column where all values
are empty string ""), `AbstractCompressionCodec.compress()` writes an 8-byte
buffer with `uncompressed_length = 0` as a "shortcut for empty buffer":

https://github.com/apache/arrow-java/blob/main/vector/src/main/java/org/apache/arrow/vector/compression/AbstractCompressionCodec.java#L32-L39

```java
if (uncompressedBuffer.writerIndex() == 0L) {
// shortcut for empty buffer
compressedBuffer.setLong(0, 0); // prefix = 0
...
}
```

This has been present since the initial implementation (ARROW-11899, 2021).

The Java `decompress()` handles this correctly (`if size==0 return empty`),
but **C++ and Python Arrow readers do not recognize `prefix=0`**. They attempt
to decompress 0 bytes of data, which fails:

- C++ (Arrow 1.0.0 ~ latest): `IOError: Lz4 compressed input contains less than one frame`
- PyArrow 21.0: same error

### Reproduction

Write an Arrow IPC stream with LZ4_FRAME (or ZSTD) compression where **one
string column has all values = ""** (empty string, not null). The string data
buffer has `writerIndex = 0`, triggering the empty buffer path.

```java
// Writer
ArrowStreamWriter writer = new ArrowStreamWriter(root, null, channel,
IpcOption.DEFAULT, CommonsCompressionFactory.INSTANCE, CodecType.LZ4_FRAME);

// All rows: stringVector.setSafe(i, "".getBytes());
```

Reading with C++ or Python fails at the first RecordBatch.

### Root cause

The Arrow IPC compression format defines:
- `prefix > 0`: compressed data follows, decompress to `prefix` bytes
- `prefix = -1`: buffer stored uncompressed (sentinel)
- `prefix = 0`: **undefined** — not in spec, not handled by C++/Python

Java writes `prefix=0` for empty buffers, but only Java itself knows how to
read it back. C++/Python treat it as "0 bytes to decompress" → fail.

### Suggested fix

Change the empty buffer path to use `-1` sentinel (which all readers support):

```java
if (uncompressedBuffer.writerIndex() == 0L) {
ArrowBuf compressedBuffer = allocator.buffer(SIZE_OF_UNCOMPRESSED_LENGTH);
compressedBuffer.setLong(0, -1L); // Use -1 instead of 0
compressedBuffer.writerIndex(SIZE_OF_UNCOMPRESSED_LENGTH);
uncompressedBuffer.close();
return compressedBuffer;
}
```

When a reader sees `prefix=-1`, it returns an empty/zero-length slice — which
is correct for an originally empty buffer.

### Environment

- Affected: All Arrow Java versions with IPC compression (1.0.0+)
- Readers that fail: Arrow C++ (all versions), PyArrow (all versions)
- Codec: Both LZ4_FRAME and ZSTD

### Related

- #1116 — similar symptom (prefix=0) but different root cause (race condition
in vector reuse, not the intentional empty buffer path)
- apache/arrow#15102 — C++ DecompressBuffer fix for prefix=-1 (does not
handle prefix=0)
```

貢獻指南

開啟貢獻指南

研究方向

從 vector/src/main/java/org/apache/arrow/vector/compression/AbstractCompressionCodec.java 中的空緩衝區分支開始,將其前綴處理與文件中記載的 -1 sentinel 進行比較。使用 LZ4_FRAME 或 ZSTD,透過一個僅包含空字串的 string 欄位重現此情況,然後驗證 C++ 和 Python reader 能夠讀取產生的 IPC 串流,且不會發生解壓縮錯誤。

由索引模型根據 Issue 內容生成。

評估

技術堆疊
java
領域
data-engineering
Issue 類型
缺陷
難度
2/5
預估耗時
1-3 小時
活躍度
冷清
描述清晰度
描述清楚
新手友好度
68/100

把新 issue 寄到你的電子郵件信箱

精選適合新手參與的 GitHub issue 摘要。