airbytehq / airbytehq/airbyte-api-python-sdk
ConnectionSyncModeEnum missing support for 'full_refresh_overwrite_deduped' sync mode
- Vorherrschende Sprache
- Python
- Sterne
- 61
- Forks
- 27
- Ø Merge
- 4 Min.
- Gemergte PRs (30 T.)
- 2
Beschreibung
## Description
The SDK's `ConnectionSyncModeEnum` doesn't support the `full_refresh_overwrite_deduped` sync mode that is returned by Airbyte instances, causing connection listing operations to fail.
## Steps to Reproduce
1. Initialize AirbyteAPI client
2. Call `list_connections()` on a workspace that has connections using the `full_refresh_overwrite_deduped` sync mode
3. Observe the error when trying to deserialize the response
## Expected Behavior
The SDK should successfully parse all sync modes returned by the Airbyte API, including `full_refresh_overwrite_deduped`. See [here](https://docs.airbyte.com/platform/using-airbyte/core-concepts/sync-modes/full-refresh-overwrite-deduped)
## Actual Behavior
The SDK throws a ValueError:
```python
ValueError: 'full_refresh_overwrite_deduped' is not a valid ConnectionSyncModeEnum
```
## Verification of Other Endpoints
Using the same client configuration and authentication token, the following endpoints work successfully:
- `list_workspaces()` - Returns workspace data correctly, passed into the list_connections call
- `health_check()` - Confirms API is accessible and working
This confirms the issue is specifically with the ConnectionSyncModeEnum implementation and not related to authentication, connectivity, or general SDK configuration.
## Current SDK Supported Modes
The SDK currently only supports:
- full_refresh_overwrite
- full_refresh_append
- incremental_append
- incremental_deduped_history
## Environment Information
- SDK Version: 0.52.2
- Python Version: 3.12
- Operating System: Darwin 24.4.0
## Error Stack Trace
```python
Traceback (most recent call last):
File "/usr/local/lib/python3.12/enum.py", line 1158, in __new__
raise ve_exc
ValueError: 'full_refresh_overwrite_deduped' is not a valid ConnectionSyncModeEnum
```
## Additional Context
This appears to be a mismatch between the SDK's enum definitions and the actual sync modes supported by Airbyte instances. The SDK needs to be updated to include all possible sync modes that Airbyte can return.