Description

Expected Behavior

There should be no errors and all pods should come up properly.

Actual Behavior

Events:
  Type     Reason        Age                  From                   Message
  ----     ------        ----                 ----                   -------
  Warning  FailedCreate  5m1s (x18 over 15m)  replicaset-controller  Error creating: pods "tekton-pipelines-controller-6dccf778c7-" is forbidden: unable to validate against any security context constraint: [provider "anyuid": Forbidden: not usable by user or serviceaccount, provider restricted-v2: .containers[0].runAsUser: Invalid value: 65532: must be in the ranges: [1000220000, 1000229999], provider restricted-v3: .spec.securityContext.hostUsers: Invalid value: null: Host Users must be set to false, provider "restricted": Forbidden: not usable by user or serviceaccount, provider "nonroot-v2": Forbidden: not usable by user or serviceaccount, provider "nonroot": Forbidden: not usable by user or serviceaccount, provider "hostmount-anyuid": Forbidden: not usable by user or serviceaccount, provider "hostnetwork-v2": Forbidden: not usable by user or serviceaccount, provider "hostnetwork": Forbidden: not usable by user or serviceaccount, provider "hostaccess": Forbidden: not usable by user or serviceaccount, provider "privileged": Forbidden: not usable by user or serviceaccount]

The TektonConfig resource is looking like this:

$ k get tektonconfig config
NAME     VERSION   READY   REASON
config   v0.80.0   False   Components not in ready state: TektonPipeline: reconcile again and proceed
$

Steps to Reproduce the Problem

  1. Install the tekton-operator via https://infra.tekton.dev/tekton-releases/operator/latest/release.yaml
  2. Create the TektonConfig from https://raw.githubusercontent.com/tektoncd/operator/main/config/crs/openshift/config/all/operator_v1alpha1_config_cr.yaml
  3. There are deployments and replicaSets, but no pods due to the SCC errors.

Additional Info

Kubernetes version: v1.34.7

This is a OpenShift MicroShift singlenode machine, so there is no GUI and no marketplace to install the official RedHat Pipelines Operator.

Kind Regards,
Johannes

Contributor guide

Open the contributing guide

First steps

  1. Read the whole issue, then the project's contributing guide.
  2. Comment on the issue to say you are picking it up — it saves two people doing the same work.
  3. Fork the repository and make your change on a branch.
  4. Open a pull request that references the issue number.

Assessment

This issue has not been assessed yet.

Get new issues in your inbox

A short digest of beginner-friendly GitHub issues.