domthom21 / domthom21/eurocodedesign

[BUG] Slender webs completely in tension are falsely classified

Open
#96 0 comments 0 reactions 0 assignees View on GitHub
bug
Dominant language
Python
Stars
8
Forks
1
PR merge metrics
No merged PRs in 30d

Description

**Describe the bug**
`classify_dsup_element`` falsely classifies tension loaded slender web elements as class 4 instead of class 1 because the value of psi is larger than 1.

**Expected behavior**
when psi is larger than 1 the web should be classified as QK1

**Additional context**
EC3-1-1 Table 5.2