commaai / commaai/opendbc

[ISO-TP] Number of consecutive frames is wrong when FC contains Block Size

Open
#1,682 0 comments 0 reactions 0 assignees View on GitHub
Dominant language
Python
Stars
3.4k
Forks
2.3k
Avg merge
3d 2h
Merged PRs (30d)
38

Description

When an ECU responds with a non zero Block Size in the flow control, the number of consecutive frames might be wrong. E.g. if the ECU responds with a block size of 8, but there are less consecutive frames to send it will send zeroes instead.

Example:

```python
uds_client._uds_request(0x23, None, b"\x00" * 7)
```

Debug output:

```
ISO-TP: REQUEST - 0x7b7 0x2300000000000000
ISO-TP: TX - first frame - 0x7b7
CAN-TX: 0x7b7 - 0x1008230000000000
CAN-RX: 0x7bf - 0x300814aaaaaaaaaa
ISO-TP: RX - flow control continue - 0x7b7
CAN-TX: 0x7b7 - 0x2100000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2200000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2300000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2400000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2500000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2600000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2700000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2800000000000000
ISO-TP: TX - consecutive frame - 0x7b7 idx=8 done=True
CAN-RX: 0x7bf - 0x037f2331aaaaaaaa
ISO-TP: RX - single frame - 0x7bf idx=0 done=True
ISO-TP: RESPONSE - 0x7bf 0x7f2331
```

I think the fix should be to change https://github.com/commaai/panda/blob/master/python/uds.py#L535 to
```python
end = min(start + count * num_bytes, self.tx_len) if count > 0 else self.tx_len
```
But don't have time right now to verify.