[ISO-TP] Number of consecutive frames is wrong when FC contains Block Size
- Dominant language
- Python
- Stars
- 3.4k
- Forks
- 2.3k
- Avg merge
- 3d 2h
- Merged PRs (30d)
- 38
Description
When an ECU responds with a non zero Block Size in the flow control, the number of consecutive frames might be wrong. E.g. if the ECU responds with a block size of 8, but there are less consecutive frames to send it will send zeroes instead.
Example:
```python
uds_client._uds_request(0x23, None, b"\x00" * 7)
```
Debug output:
```
ISO-TP: REQUEST - 0x7b7 0x2300000000000000
ISO-TP: TX - first frame - 0x7b7
CAN-TX: 0x7b7 - 0x1008230000000000
CAN-RX: 0x7bf - 0x300814aaaaaaaaaa
ISO-TP: RX - flow control continue - 0x7b7
CAN-TX: 0x7b7 - 0x2100000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2200000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2300000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2400000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2500000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2600000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2700000000000000
CAN-TX: delay - 0.02
CAN-TX: 0x7b7 - 0x2800000000000000
ISO-TP: TX - consecutive frame - 0x7b7 idx=8 done=True
CAN-RX: 0x7bf - 0x037f2331aaaaaaaa
ISO-TP: RX - single frame - 0x7bf idx=0 done=True
ISO-TP: RESPONSE - 0x7bf 0x7f2331
```
I think the fix should be to change https://github.com/commaai/panda/blob/master/python/uds.py#L535 to
```python
end = min(start + count * num_bytes, self.tx_len) if count > 0 else self.tx_len
```
But don't have time right now to verify.