apache / apache/seatunnel

[Bug][Connector-V2][Paimon] DELETE records may remain when multiple Flink sink writers write to the same bucket

Open
#12,243 4 comments 0 reactions 1 assignee Claimed by @zhangshenghang View on GitHub
bug
Dominant language
Java
Stars
9.7k
Forks
2.4k
Avg merge
3d 13h
Merged PRs (30d)
203

Description

### Search before asking

- [x] I had searched in the [issues](https://github.com/apache/seatunnel/issues?q=is%3Aissue+label%3A%22bug%22) and found no similar issues.

### What happened

### Problem

When writing CDC data to a Paimon primary-key table through SeaTunnel on Flink with multiple sink writers, deleted records may remain in Paimon after the writes are committed.

Expected: a committed DELETE removes the corresponding primary key.
Actual: the deleted record is still returned by a fresh Paimon read.

### Reproduction evidence

A downstream Flink MiniCluster regression uses two source subtasks, two sink writers, a fixed-bucket Paimon table (`bucket = 1`), and synthetic INSERT/UPDATE/DELETE events.

After inserting 100 distinct records and deleting one, the legacy sink path without bucket-aware routing fails the read-back assertion:

expected: <99> but was: <100>

The test exercises the actual SeaTunnel Flink sink path and Paimon connector with a local filesystem warehouse.

This was reproduced on a customized SeaTunnel 2.3.13-based branch, not a clean upstream dev checkout. The regression test is currently downstream-only.

### Suspected cause

The legacy Flink sink path appears not to guarantee a single writer owner for each physical Paimon table/partition/bucket. An INSERT and a subsequent DELETE for the same key may therefore reach different writers targeting the same bucket.

The corresponding downstream regression passes after adding bucket-aware routing before the sink. This supports the diagnosis, but is not yet an upstream-verified fix.

### Related issues

I checked #7769, #8565, #9595, #10978 and #11077. They discuss single-writer configurations, dynamic buckets or sharing writers across logical tables; I did not find an exact duplicate of this fixed-bucket DELETE case.

Should the Flink integration enforce table/partition/bucket-aware routing before the Paimon sink? If this is already tracked elsewhere, please point me to the existing issue.

### SeaTunnel Version

SeaTunnel 2.3.13-based customized downstream build.

The failing reproduction uses a legacy-path control in the downstream regression suite.

Reproduction on a clean upstream release or the latest upstream dev branch has not yet been performed.

### SeaTunnel Config

```conf
The current reproducible case is a programmatic Flink MiniCluster regression,
rather than a standalone SeaTunnel HOCON job.

Test configuration:

- Source parallelism: 2
- Sink parallelism: 2
- Connector: Paimon
- Warehouse: temporary local filesystem directory
- Database: routing_test
- Table: table_0
- Primary key: (id, part)
- Paimon table options:
bucket = 1
write-only = true

The test sends synthetic INSERT/UPDATE/DELETE records through the actual
SeaTunnel Flink sink path, commits the writes, and reads the Paimon table back.

The legacy control omits the downstream bucket-aware routing before the sink.

No production credentials, endpoints or business data are required by this test.
```

### Running Command

```shell
# Downstream regression control; this test is not available in upstream SeaTunnel.
# Requires the downstream source tree and its built module dependencies.
# The legacy control is expected to fail the DELETE correctness assertion.

mvn -f seatunnel-connectors-v2/connector-paimon/pom.xml \
-Dskip.spotless=true \
-Dissue113.test.legacy-routing=true \
-Dtest=PaimonFlinkBucketRoutingTest#shouldRouteSingleBucketThroughActualFlinkSink \
test
```

### Error Exception

```log
The reported symptom is incorrect persisted data, rather than a connector exception.

The downstream legacy-path regression failed with:

expected: <99> but was: <100>

This is a test assertion failure from reading the Paimon table after the write/delete sequence,
not a production exception stack trace.
```

### Zeta or Flink or Spark Version

Flink 1.18.1

SeaTunnel Flink 1.15 adapter / starter integration.
Paimon 1.1.1.

### Java or Scala Version

Java 8

### Screenshots

_No response_

### Are you willing to submit PR?

- [ ] Yes I am willing to submit a PR!

### Code of Conduct

- [x] I agree to follow this project's [Code of Conduct](https://www.apache.org/foundation/policies/conduct)

Contributor guide

No contributing guide indexed for this repository

Assessment

This issue has not been assessed yet.

Get new issues in your inbox