NatLabRockies / NatLabRockies/ResStock.github.io
Update unmet hours description
@jbrossman is already working on this.
Since Nov 18, 2025.
- Dominant language
- SCSS
- Stars
- 0
- Forks
- 7
- Avg merge
- 2m
- Merged PRs (30d)
- 2
Description
Note from Scott: "Unmet load hours in EnergyPlus represent the number of hours during which a thermal zone's operative temperature falls outside the desired heating or cooling setpoint range."
That's close but not quite right. It's based on the thermal zone's drybulb air temperature, not operative temperature. (Operative temperature incorporates the mean radiant temperature and is used as a thermal comfort metric. It wouldn't make sense to compare it to the heating/cooling setpoints.)
TODO: fix this once decide on new column name for unmet hours
Contributor guide
No contributing guide indexed for this repository
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
Assessment
This issue has not been assessed yet.