NatLabRockies / NatLabRockies/OpenStudio

AirLoopHVAC:Unitary Water to Air Heat Pump Electric Reheat Issue

Open
#2,996 4 comments 1 reaction 1 assignee View on GitHub

@kbenne is already working on this.

Since Feb 15, 2018.

component - HVAC severity - Normal Bug
Dominant language
C++
Stars
646
Forks
237
Avg merge
3d 11h
Merged PRs (30d)
10

Description

If I use the AirLoopHVAC:Unitary Water to Air Heat Pump as a wrapper with load control there is not an issue. Once I change the control type to setpoint the electric reheat coils gives an error that there is not a setpoint manager on the control node. The field for setting the control node is unavailable. I can set a control node in EnergyPlus but not in OpenStudio. I am using OS 2.4.0. I am attaching files for a small case where I am trying to setup a geothermal DOAS unit that is using setpoint managers to control to a fixed leaving air temperature via setpoint manager scheduled. Again, I can get it to work in E+ plus I need it to work in OS so that I can use the GLHEPro measures.
Test Case Doas.zip