Koenkk / Koenkk/zigbee2mqtt

[0x0210 (Icon2) / Danfoss] ???

Open
#32,944 0 comments 0 reactions 0 assignees View on GitHub

Nobody has claimed this yet.

problem
Dominant language
TypeScript
Stars
15.7k
Forks
2k
Avg merge
18h 55m
Merged PRs (30d)
35

Description

What happened?

Endpoint do not take name from Danfoss config

What did you expect to happen?

No response

How to reproduce it (minimal and precise)

No response

Zigbee2MQTT version

2.13.0 (unknown)

Adapter firmware version

{"build":397,"ezsp":14,"major":8,"minor":0,"patch":2,"revision":"8.0.2 [GA]","special":0,"type":170}

Adapter

EmberZNet

Setup

os: #1 SMP PREEMPT_DYNAMIC Thu Jul 30 12:31:10 UTC 2026 - 6.18.39-haos - x64
node: v24.18.1
ha: true

Device database.db entry

No response

Debug log

No response

Notes
Device

definition: Icon2 - Danfoss (v0.0.0)
software_build_id: 01.82.0016.01.36
date_code: 20471619
endpoints:

{"1":{"bindings":[],"clusters":{"input":["genBasic","genPowerCfg","genIdentify","hvacThermostat","hvacUserInterfaceCfg","msTemperatureMeasurement","msRelativeHumidity","haDiagnostic"],"output":[]},"configured_reportings":[{"attribute":"batteryPercentageRemaining","cluster":"genPowerCfg","maximum_report_interval":65000,"minimum_report_interval":3600,"reportable_change":0},{"attribute":"localTemp","cluster":"hvacThermostat","maximum_report_interval":3600,"minimum_report_interval":0,"reportable_change":10},{"attribute":"occupiedHeatingSetpoint","cluster":"hvacThermostat","maximum_report_interval":3600,"minimum_report_interval":0,"reportable_change":10},{"attribute":"measuredValue","cluster":"msTemperatureMeasurement","maximum_report_interval":3600,"minimum_report_interval":10,"reportable_change":10},{"attribute":"measuredValue","cluster":"msRelativeHumidity","maximum_report_interval":3600,"minimum_report_interval":10,"reportable_change":100},{"attribute":"danfossOutputStatus","cluster":"hvacThermostat","maximum_report_interval":3600,"minimum_report_interval":0,"reportable_change":1}],"scenes":[]},"2":{"bindings":[{"cluster":"genPowerCfg","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1","type":"endpoint"}},{"cluster":"hvacThermostat","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1","type":"endpoint"}},{"cluster":"hvacUserInterfaceCfg","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1","type":"endpoint"}},{"cluster":"msTemperatureMeasurement","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1","type":"endpoint"}},{"cluster":"msRelativeHumidity","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1","type":"endpoint"}}],"clusters":{"input":["genBasic","genPowerCfg","genIdentify","hvacThermostat","hvacUserInterfaceCfg","msTemperatureMeasurement","msRelativeHumidity","haDiagnostic"],"output":[]},"configured_reportings":[{"attribute":"batteryPercentageRemaining","cluster":"genPowerCfg","maximum_report_interval":65000,"minimum_report_interval":3600,"reportable_change":0},{"attribute":"localTemp","cluster":"hvacThermostat","maximum_report_interval":3600,"minimum_report_interval":0,"reportable_change":10},{"attribute":"occupiedHeatingSetpoint","cluster":"hvacThermostat","maximum_report_interval":3600,"minimum_report_interval":0,"reportable_change":10},{"attribute":"measuredValue","cluster":"msTemperatureMeasurement","maximum_report_interval":3600,"minimum_report_interval":10,"reportable_change":10},{"attribute":"measuredValue","cluster":"msRelativeHumidity","maximum_report_interval":3600,"minimum_report_interval":10,"reportable_change":100},{"attribute":"danfossOutputStatus","cluster":"hvacThermostat","maximum_report_interval":3600,"minimum_report_interval":0,"reportable_change":1}],"scenes":[]},"3":{"bindings":[{"cluster":"genPowerCfg","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1","type":"endpoint"}},{"cluster":"hvacThermostat","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1","type":"endpoint"}},{"cluster":"hvacUserInterfaceCfg","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1","type":"endpoint"}},{"cluster":"msTemperatureMeasurement","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1","type":"endpoint"}},{"cluster":"msRelativeHumidity","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1","type":"endpoint"}}],"clusters":{"input":["genBasic","genPowerCfg","genIdentify","hvacThermostat","hvacUserInterfaceCfg","msTemperatureMeasurement","msRelativeHumidity","haDiagnostic"],"output":[]},"configured_reportings":[{"attribute":"batteryPercentageRemaining","cluster":"genPowerCfg","maximum_report_interval":65000,"minimum_report_interval":3600,"reportable_change":0},{"attribute":"localTemp","cluster":"hvacThermostat","maximum_report_interval":3600,"minimum_report_interval":0,"reportable_change":10},{"attribute":"occupiedHeatingSetpoint","cluster":"hvacThermostat","maximum_report_interval":3600,"minimum_report_interval":0,"reportable_change":10},{"attribute":"measuredValue","cluster":"msTemperatureMeasurement","maximum_report_interval":3600,"minimum_report_interval":10,"reportable_change":10},{"attribute":"measuredValue","cluster":"msRelativeHumidity","maximum_report_interval":3600,"minimum_report_interval":10,"reportable_change":100},{"attribute":"danfossOutputStatus","cluster":"hvacThermostat","maximum_report_interval":3600,"minimum_report_interval":0,"reportable_change":1}],"scenes":[]},"4":{"bindings":[{"cluster":"genPowerCfg","target":{"endpoint":1,"ieee_address":"0x7c31fafffed133a1

Contributor guide

Open the contributing guide

First steps

  1. Read the whole issue, then the project's contributing guide.
  2. Comment on the issue to say you are picking it up — it saves two people doing the same work.
  3. Fork the repository and make your change on a branch.
  4. Open a pull request that references the issue number.

Research direction

Start by locating the Danfoss Icon2 device definition and its endpoint/name handling. Compare that definition with the supplied endpoint data and investigate why the endpoint does not use the Danfoss configuration name; obtain a debug log or minimal reproduction to confirm the behavior. Done means the endpoint name is taken from the configuration for this device.

Written by the indexing model from the issue text.

Assessment

Tech stack
typescript
Domain
embedded-iot
Issue type
Bug
Difficulty
3/5
Estimated time
1-2 days
Activity status
Active
Clarity
Needs clarification
Newbie friendliness
42/100

Get new issues in your inbox

A short digest of beginner-friendly GitHub issues.