Koenkk / Koenkk/zigbee2mqtt

Valve actuator ZN231392 _TZ3000_iedbgyxt led not light after last update

Open
#32,847 0 comments 0 reactions 0 assignees View on GitHub

Nobody has claimed this yet.

problem
Dominant language
TypeScript
Stars
15.7k
Forks
2k
Avg merge
18h 55m
Merged PRs (30d)
35

Description

What happened?

Valve actuator ZN231392 _TZ3000_iedbgyxt led not light after last update. Then switch on/off off off/on on set led not light at all. Repair not affected.

What did you expect to happen?

No response

How to reproduce it (minimal and precise)

No response

Zigbee2MQTT version

2.13.0-1

Adapter firmware version

20240710

Adapter

ZStack3x0

Setup

Z2M as add-on, x86-64, haos

Device database.db entry

{"id":18,"type":"Router","ieeeAddr":"0xa4c1385a815d47fa","nwkAddr":65176,"manufId":4417,"manufName":"_TZ3000_iedbgyxt","powerSource":"Mains (single phase)","modelId":"TS0001","epList":[1,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":256,"inClusterList":[3,4,5,6,57344,57345,0],"outClusterList":[25,10],"clusters":{"57344":{"attributes":{"53251":"AAAA"}},"genOnOff":{"attributes":{"32768":0,"onOff":1,"moesStartUpOnOff":0,"onTime":0,"offWaitTime":0,"tuyaBacklightMode":1,"tuyaBacklightSwitch":1}},"genBasic":{"attributes":{"65534":0,"manufacturerName":"_TZ3000_iedbgyxt","zclVersion":3,"appVersion":80,"modelId":"TS0001","powerSource":1}},"manuSpecificTuya_3":{"attributes":{"powerOnBehavior":0,"switchType":0}},"manuSpecificTuya3":{"attributes":{"powerOnBehavior":0,"switchType":0}}},"binds":[],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":80,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"interviewState":"SUCCESSFUL","meta":{"configured":332242049},"lastSeen":1786720970407}

Debug log

No response

Notes

No response

Contributor guide

Open the contributing guide

First steps

  1. Read the whole issue, then the project's contributing guide.
  2. Comment on the issue to say you are picking it up — it saves two people doing the same work.
  3. Fork the repository and make your change on a branch.
  4. Open a pull request that references the issue number.

Research direction

No source file, test, reproduction steps, or debug log is provided. Start by reproducing the LED failure with the ZN231392 TS0001 device after the update, using the database entry and adapter details as context. Collect a debug log and compare the device's LED behavior when switching on and off; done means the LED responds correctly after the update.

Written by the indexing model from the issue text.

Assessment

Tech stack
typescript
Domain
embedded-iot
Issue type
Bug
Difficulty
4/5
Estimated time
3-5 days
Activity status
Quiet
Clarity
Needs clarification
Newbie friendliness
35/100

Get new issues in your inbox

A short digest of beginner-friendly GitHub issues.