[TS011F (TO-Q-SY2-163JZT) / _TZ3000_cayepv1a] ???
Nobody has claimed this yet.
- Dominant language
- TypeScript
- Stars
- 15.7k
- Forks
- 2k
- Avg merge
- 18h 55m
- Merged PRs (30d)
- 35
Description
What happened?
ricevo questo errore quando cerco di impstare le soglie di sicureza sul dispositivo
tongo/set(temperature breaker): reading 'tostring' 18:56 11/08/2026 1
What did you expect to happen?
mi aspettavo che variasse le soglie senza dare errore
How to reproduce it (minimal and precise)
No response
Zigbee2MQTT version
2.13.0 (unknown)
Adapter firmware version
{"maintrel":1,"majorrel":2,"minorrel":7,"product":1,"revision":20240710,"transportrev":2}
Adapter
ZStack3x0
Setup
os: #1 SMP PREEMPT_DYNAMIC Thu Jul 30 12:44:18 UTC 2026 - 6.18.39-haos - x64
node: v24.18.1
ha: true
Device database.db entry
No response
Debug log
No response
Notes
Device
definition: TO-Q-SY2-163JZT - Tongou (v0.0.0)
software_build_id: undefined
date_code: ``
endpoints:
{"1":{"bindings":[{"cluster":"msTemperatureMeasurement","target":{"endpoint":1,"ieee_address":"0x00124b003eaebcca","type":"endpoint"}},{"cluster":"genOnOff","target":{"endpoint":1,"ieee_address":"0x00124b003eaebcca","type":"endpoint"}},{"cluster":"haElectricalMeasurement","target":{"endpoint":1,"ieee_address":"0x00124b003eaebcca","type":"endpoint"}},{"cluster":"seMetering","target":{"endpoint":1,"ieee_address":"0x00124b003eaebcca","type":"endpoint"}}],"clusters":{"input":["genBasic","genIdentify","genGroups","genScenes","genOnOff","seMetering","haElectricalMeasurement","msTemperatureMeasurement","57344","manuSpecificTuya3"],"output":["genOta","genTime"]},"configured_reportings":[{"attribute":"rmsVoltage","cluster":"haElectricalMeasurement","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":5},{"attribute":"rmsCurrent","cluster":"haElectricalMeasurement","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":50},{"attribute":"activePower","cluster":"haElectricalMeasurement","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":10},{"attribute":"currentSummDelivered","cluster":"seMetering","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":257}],"scenes":[]},"242":{"bindings":[],"clusters":{"input":[],"output":["greenPower"]},"configured_reportings":[],"scenes":[]}}
Health
time: Tue Aug 11 2026 19:49:38 GMT+0200 (Ora legale dell’Europa centrale)
os.load_average: 0, 0, 0
os.memory_percent: 16.6409
process.memory_percent: 2.3722
process.uptime_sec: 22326
{"leave_count":1,"messages":199,"messages_per_sec":0.0203,"network_address_changes":0}
Contributor guide
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
Research direction
Start by reproducing the threshold-setting error for the Tongou TO-Q-SY2-163JZT device, then inspect its device definition and collect the missing database entry and debug log. Done means the temperature breaker thresholds can be changed without the reported error.
Written by the indexing model from the issue text.
Assessment
- Tech stack
- typescript
- Domain
- embedded-iot
- Issue type
- Bug
- Difficulty
- 4/5
- Estimated time
- 3-5 days
- Activity status
- Quiet
- Clarity
- Needs clarification
- Newbie friendliness
- 25/100