Koenkk / Koenkk/zigbee2mqtt

[TS011F (TO-Q-SY2-163JZT) / _TZ3000_cayepv1a] ???

Open
#32,818 0 comments 0 reactions 0 assignees View on GitHub

Nobody has claimed this yet.

problem
Dominant language
TypeScript
Stars
15.7k
Forks
2k
Avg merge
18h 55m
Merged PRs (30d)
35

Description

What happened?

ricevo questo errore quando cerco di impstare le soglie di sicureza sul dispositivo

tongo/set(temperature breaker): reading 'tostring' 18:56 11/08/2026 1

What did you expect to happen?

mi aspettavo che variasse le soglie senza dare errore

How to reproduce it (minimal and precise)

No response

Zigbee2MQTT version

2.13.0 (unknown)

Adapter firmware version

{"maintrel":1,"majorrel":2,"minorrel":7,"product":1,"revision":20240710,"transportrev":2}

Adapter

ZStack3x0

Setup

os: #1 SMP PREEMPT_DYNAMIC Thu Jul 30 12:44:18 UTC 2026 - 6.18.39-haos - x64
node: v24.18.1
ha: true

Device database.db entry

No response

Debug log

No response

Notes
Device

definition: TO-Q-SY2-163JZT - Tongou (v0.0.0)
software_build_id: undefined
date_code: ``
endpoints:

{"1":{"bindings":[{"cluster":"msTemperatureMeasurement","target":{"endpoint":1,"ieee_address":"0x00124b003eaebcca","type":"endpoint"}},{"cluster":"genOnOff","target":{"endpoint":1,"ieee_address":"0x00124b003eaebcca","type":"endpoint"}},{"cluster":"haElectricalMeasurement","target":{"endpoint":1,"ieee_address":"0x00124b003eaebcca","type":"endpoint"}},{"cluster":"seMetering","target":{"endpoint":1,"ieee_address":"0x00124b003eaebcca","type":"endpoint"}}],"clusters":{"input":["genBasic","genIdentify","genGroups","genScenes","genOnOff","seMetering","haElectricalMeasurement","msTemperatureMeasurement","57344","manuSpecificTuya3"],"output":["genOta","genTime"]},"configured_reportings":[{"attribute":"rmsVoltage","cluster":"haElectricalMeasurement","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":5},{"attribute":"rmsCurrent","cluster":"haElectricalMeasurement","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":50},{"attribute":"activePower","cluster":"haElectricalMeasurement","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":10},{"attribute":"currentSummDelivered","cluster":"seMetering","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":257}],"scenes":[]},"242":{"bindings":[],"clusters":{"input":[],"output":["greenPower"]},"configured_reportings":[],"scenes":[]}}
Health

time: Tue Aug 11 2026 19:49:38 GMT+0200 (Ora legale dell’Europa centrale)
os.load_average: 0, 0, 0
os.memory_percent: 16.6409
process.memory_percent: 2.3722
process.uptime_sec: 22326

{"leave_count":1,"messages":199,"messages_per_sec":0.0203,"network_address_changes":0}

Contributor guide

Open the contributing guide

First steps

  1. Read the whole issue, then the project's contributing guide.
  2. Comment on the issue to say you are picking it up — it saves two people doing the same work.
  3. Fork the repository and make your change on a branch.
  4. Open a pull request that references the issue number.

Research direction

Start by reproducing the threshold-setting error for the Tongou TO-Q-SY2-163JZT device, then inspect its device definition and collect the missing database entry and debug log. Done means the temperature breaker thresholds can be changed without the reported error.

Written by the indexing model from the issue text.

Assessment

Tech stack
typescript
Domain
embedded-iot
Issue type
Bug
Difficulty
4/5
Estimated time
3-5 days
Activity status
Quiet
Clarity
Needs clarification
Newbie friendliness
25/100