[TS011F (JR-ZPM01) / _TZ3000_ww6drja5] ??? : Since Z2M Update to 2.13.0, Energy counter not updated properly while Power does
Nobody has claimed this yet.
- Dominant language
- TypeScript
- Stars
- 15.7k
- Forks
- 2k
- Avg merge
- 18h 55m
- Merged PRs (30d)
- 35
Description
What happened?
Hello,
Since I upgraded Zigbee2Mqtt last Aug Srst to 2.13.0, I noticed my smart plug did not update energy meter correctly to HA (2026.07.04)
The smart plug monitors my solar plug and play panes.
Till I upgraded Zigbee2Mqtt to 2.13.0, my solar energy was correctly reported in HA and gaphs.
Sample : Aug 1rst
Now, same graph looks like
Zigbee2Mqtt version info
What did you expect to happen?
Zigmee2Mqtt Upgrade to 2.13.0
How to reproduce it (minimal and precise)
.
Zigbee2MQTT version
2.13.0 (unknown)
Adapter firmware version
{"maintrel":1,"majorrel":2,"minorrel":7,"product":1,"revision":20210708,"transportrev":2}
Adapter
ZStack3x0
Setup
os: #1 SMP PREEMPT_DYNAMIC Thu Jul 30 12:31:10 UTC 2026 - 6.18.39-haos - x64
node: v24.18.1
ha: true
Device database.db entry
No response
Debug log
No response
Notes
Device
definition: JR-ZPM01 - Girier (v0.0.1)
software_build_id: 1.0.5
date_code: undefined
endpoints:
{"1":{"bindings":[{"cluster":"genOnOff","target":{"endpoint":1,"ieee_address":"0x00124b002e1df60b","type":"endpoint"}},{"cluster":"seMetering","target":{"endpoint":1,"ieee_address":"0x00124b002e1df60b","type":"endpoint"}},{"cluster":"haElectricalMeasurement","target":{"endpoint":1,"ieee_address":"0x00124b002e1df60b","type":"endpoint"}}],"clusters":{"input":["genBasic","genIdentify","genGroups","genScenes","genOnOff","genTime","57344","seMetering","haElectricalMeasurement","touchlink","6280"],"output":["genOta"]},"configured_reportings":[{"attribute":"currentSummDelivered","cluster":"seMetering","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":257},{"attribute":"rmsVoltage","cluster":"haElectricalMeasurement","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":5},{"attribute":"rmsCurrent","cluster":"haElectricalMeasurement","maximum_report_interval":3600,"minimum_report_interval":5,"reportable_change":50}],"scenes":[]}}
Health
time: Mon Aug 03 2026 12:04:36 GMT+0200 (Central European Summer Time)
os.load_average: 0.33, 0.19, 0.12
os.memory_percent: 12.4211
process.memory_percent: 1.5621
process.uptime_sec: 148806
{"leave_count":0,"messages":20787,"messages_per_sec":0.1397,"network_address_changes":0}
Contributor guide
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
Research direction
Start with the JR-ZPM01 Girier device definition and the issue's 2.13.0 reports, comparing the seMetering currentSummDelivered behavior with the working power values. Reproduce using the provided adapter, setup, and device details, then inspect the comment thread for additional evidence. Done means the energy counter updates correctly while power reporting remains intact.
Written by the indexing model from the issue text.
Assessment
- Tech stack
- typescript
- Domain
- embedded-iot
- Issue type
- Bug
- Difficulty
- 4/5
- Estimated time
- 3-5 days
- Activity status
- Active
- Clarity
- Needs clarification
- Newbie friendliness
- 38/100