[TS0207 (TS0207_water_leak_detector) / _TZ3000_otwpdq1d] ???
Nobody has claimed this yet.
- Dominant language
- TypeScript
- Stars
- 15.7k
- Forks
- 2k
- Avg merge
- 18h 55m
- Merged PRs (30d)
- 35
Description
What happened?
i add a zigbee device what should be the HOBEIAN ZG-223Z but it shows me in Z2M as Tuya TS0207_water_leak_detector
What did you expect to happen?
after adding the sensor it should shows up as HOBEIAN ZG-223Z
How to reproduce it (minimal and precise)
No response
Zigbee2MQTT version
2.12.1 (unknown)
Adapter firmware version
{"build":0,"ezsp":13,"major":7,"minor":5,"patch":1,"revision":"7.5.1 [GA]","special":0,"type":170}
Adapter
EmberZNet
Setup
os: #1 SMP PREEMPT_DYNAMIC Wed Jul 1 07:35:33 UTC 2026 - 6.18.37-haos - x64
node: v22.23.0
ha: true
Device database.db entry
No response
Debug log
No response
Notes
Device
definition: TS0207_water_leak_detector - Tuya (v0.0.0)
software_build_id: undefined
date_code: ``
endpoints:
{"1":{"bindings":[{"cluster":"genPowerCfg","target":{"endpoint":1,"ieee_address":"0xd878f0fffe957664","type":"endpoint"}}],"clusters":{"input":["genPowerCfg","genIdentify","ssIasZone","genBasic"],"output":["genOta","genTime"]},"configured_reportings":[{"attribute":"batteryPercentageRemaining","cluster":"genPowerCfg","maximum_report_interval":65000,"minimum_report_interval":3600,"reportable_change":0}],"scenes":[]}}
Health
time: Fri Jul 31 2026 21:53:48 GMT+0200 (Mitteleuropäische Sommerzeit)
os.load_average: 0.12, 0.07, 0.01
os.memory_percent: 38.0384
process.memory_percent: 3.4442
process.uptime_sec: 2310606
{"leave_count":6,"messages":95,"messages_per_sec":0.0728,"network_address_changes":0}
Contributor guide
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
Research direction
Start with the linked HOBEIAN ZG-223Z and Tuya TS0207_water_leak_detector device pages, then compare them with the reported endpoint and cluster data. Determine whether this device can be distinguished and represented as HOBEIAN ZG-223Z; done means it is identified with that model after pairing.
Written by the indexing model from the issue text.
Assessment
- Tech stack
- typescript
- Domain
- embedded-iot
- Issue type
- Bug
- Difficulty
- 4/5
- Estimated time
- 3-5 days
- Activity status
- Quiet
- Clarity
- Needs clarification
- Newbie friendliness
- 35/100