What happened?
device still online after stop/start of the dongle-P, but no informations are sent. no logo of connected device shown. Only the button wake/reconnection can make it work.
What did you expect to happen?
automatic reconnection after shutting down and restart the dongle
How to reproduce it (minimal and precise)
No response
Zigbee2MQTT version
2.12.0 (unknown)
Adapter firmware version
{"maintrel":1,"majorrel":2,"minorrel":7,"product":1,"revision":20250321,"transportrev":2}
Adapter
ZStack3x0
Setup
os: #1 SMP PREEMPT_DYNAMIC Thu Jun 18 16:52:30 UTC 2026 - 6.18.35-haos - x64
node: v22.22.2
ha: true
Device database.db entry
No response
Debug log
No response
Notes
Device
definition: SNZB-02D - SONOFF (v0.0.0)
software_build_id: 2.3.0
date_code: 20250116
endpoints:
{"1":{"bindings":[{"cluster":"genPollCtrl","target":{"endpoint":1,"ieee_address":"0x00124b003929d4bd","type":"endpoint"}},{"cluster":"genPowerCfg","target":{"endpoint":1,"ieee_address":"0x00124b003929d4bd","type":"endpoint"}},{"cluster":"msTemperatureMeasurement","target":{"endpoint":1,"ieee_address":"0x00124b003929d4bd","type":"endpoint"}},{"cluster":"msRelativeHumidity","target":{"endpoint":1,"ieee_address":"0x00124b003929d4bd","type":"endpoint"}}],"clusters":{"input":["genBasic","genPowerCfg","genIdentify","genPollCtrl","msTemperatureMeasurement","msRelativeHumidity","manuSpecificAmazonWWAH","customSonoffSnzb02d"],"output":["genOta"]},"configured_reportings":[{"attribute":"batteryPercentageRemaining","cluster":"genPowerCfg","maximum_report_interval":65000,"minimum_report_interval":3600,"reportable_change":10},{"attribute":"measuredValue","cluster":"msTemperatureMeasurement","maximum_report_interval":3600,"minimum_report_interval":10,"reportable_change":100},{"attribute":"measuredValue","cluster":"msRelativeHumidity","maximum_report_interval":3600,"minimum_report_interval":10,"reportable_change":100}],"scenes":[]}}
Health
time: Thu Jun 25 2026 09:37:19 GMT+0200 (heure d’été d’Europe centrale)
os.load_average: 0, 0, 0
os.memory_percent: 53.4232
process.memory_percent: 5.7756
process.uptime_sec: 9515
{"leave_count":0,"messages":17,"messages_per_sec":0.0507,"network_address_changes":0}
Contributor guide
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
Research direction
No source files or tests are named. Start by reproducing the SNZB-02D failure with the ZStack3x0 adapter after restarting the dongle-P, then collect a debug log and inspect the adapter reconnection and device-reporting paths. Done means the device reconnects automatically and resumes sending information without a manual wake or reconnection.
Written by the indexing model from the issue text.
Assessment
- Tech stack
- typescript
- Domain
- backend, embedded-iot
- Issue type
- Bug
- Difficulty
- 4/5
- Estimated time
- 3-5 days
- Activity status
- Quiet
- Clarity
- Needs clarification
- Newbie friendliness
- 35/100