FOME-Tech / FOME-Tech/fome-fw

Idle Open Loop IAC Position vs RPM Table

Open
#674 0 comments 0 reactions 0 assignees View on GitHub
enhancement
Dominant language
C
Stars
138
Forks
69
Avg merge
5d 20h
Merged PRs (30d)
4

Description

Add an open loop idle IAC position vs RPM table as a selectable option instead of a fixed base open loop IAC%. This would be particularly useful in acting as a type of feed foward to combat idle droops without needing overly active IAC PID controller (overly active IAC PID fights with CL idle timing).

Contributor guide

Open the contributing guide

Assessment

This issue has not been assessed yet.