Double solenoid ICV mode - Valve only operates from 25% to 75% duty.
Open
Low priority
- Dominant language
- C
- Stars
- 138
- Forks
- 69
- Avg merge
- 5d 20h
- Merged PRs (30d)
- 4
Description
EDIT - Updated title to correct issue. Scale seems ok but solenoid is not able to make use of the full range.
Using the slider for % opening of the IAC causes the commanded % to be doubled.
10% causes 20% duty cycle on the open solenoid, 40% causes 80% duty, any position greater than 50% saturates the output.
The close duty responds inverse so it's working as expected just double.
Checked on our current release, verified on the MCU pins with a scope.
Low priority for now, Will confirm function is ok on BMW and advise any users duty is doubled in current release.