Description

Hi All,
In a 2-node pacemaker cluster, with fence_ipmilan configured as method=cycle and action=reboot, if a node is forcibly powered off, the other node cannot perform the fence action and keeps reporting “Connection Timed out”;

After debugging, it appears that the failure of the fence action is attributed to the unsuccessful execution of the command '/var/bin/ipmitool -I lanplus -H xx.xx.xx.xx -p 623 -U Administrator -P [set] -L ADMINISTRATOR -N 2 chassis power cycle.' The error message associated with this command is: 'Set Chassis Power Control to Cycle failed: Command not supported in present state'.

Logs are follow:
`Oct 11 14:48:58 host1 pacemaker-schedulerd[2984671]: warning: Calculated transition 16611 (with warnings), saving inputs in /var/lib/pacemaker/pengine/pe-warn-2593.bz2
Oct 11 14:48:58 host1 pacemaker-controld[2984672]: notice: Requesting fencing (reboot) targeting node host2
Oct 11 14:48:58 host1 pacemaker-fenced[2984668]: notice: Client pacemaker-controld.2984672 wants to fence (reboot) host2 using any device
Oct 11 14:48:58 host1 pacemaker-fenced[2984668]: notice: Requesting peer fencing (reboot) targeting host2
Oct 11 14:48:58 host1 pacemaker-fenced[2984668]: notice: Requesting that host1 perform 'reboot' action targeting host2
Oct 11 14:48:58 host1 /fence_ipmilan[2923680]: Executing: /usr/bin/ipmitool -I lanplus -H xx.xx.xx.xx -p 623 -U Administrator -P [set] -L ADMINISTRATOR -N 2 chassis power status
Oct 11 14:48:58 host1 /fence_ipmilan[2923680]: Executing: /usr/bin/ipmitool -I lanplus -H xx.xx.xx.xx -p 623 -U Administrator -P [set] -L ADMINISTRATOR -N 2 chassis power cycle
Oct 11 14:48:58 host1 /fence_ipmilan[2923680]: Executing: /usr/bin/ipmitool -I lanplus -H xx.xx.xx.xx -p 623 -U Administrator -P [set] -L ADMINISTRATOR -N 2 chassis power cycle
Oct 11 14:49:00 host1 pacemaker-attrd[2984670]: notice: Setting ram_free[host1] in instance_attributes: 50.48 -> 226950
Oct 11 14:49:00 host1 pacemaker-controld[2984672]: notice: Transition 16611 aborted by status-1-ram_free doing modify ram_free=226950: Transient attribute change
Oct 11 14:49:00 host1 pacemaker-attrd[2984670]: notice: Setting ram_total[host1] in instance_attributes: 250.17 -> 256200
Oct 11 14:49:00 host1 /fence_ipmilan[2923680]: **Connection timed out**
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ 2024-10-11 14:48:58,324 INFO: Executing: /usr/bin/ipmitool -I lanplus -H xx.xx.xx.xx -p 623 -U Administrator -P [set] -L ADMINISTRATOR -N 2 chassis power status ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ 2024-10-11 14:48:58,381 DEBUG: 0 Chassis Power is off ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ 2024-10-11 14:48:58,382 INFO: Executing: /usr/bin/ipmitool -I lanplus -H xx.xx.xx.xx -p 623 -U Administrator -P [set] -L ADMINISTRATOR -N 2 chassis power cycle ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ 2024-10-11 14:48:58,567 DEBUG: 1 Set Chassis Power Control to Cycle failed: Command not supported in present state ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ 2024-10-11 14:48:58,567 INFO: Executing: /usr/bin/ipmitool -I lanplus -H xx.xx.xx.xx -p 623 -U Administrator -P [set] -L ADMINISTRATOR -N 2 chassis power cycle ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ 2024-10-11 14:48:58,741 DEBUG: 1 Set Chassis Power Control to Cycle failed: Command not supported in present state ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ ]
Oct 11 14:49:00 host1 pacemaker-fenced[2984668]: warning: fence_ipmilan[2923680] stderr: [ 2024-10-11 14:49:00,743 ERROR: **Connection timed out** ]`

My question is:
1. Is it appropriate to report 'Connection timed out' error here?
2. After a node (host2) is forcibly powered off, the expected result is the other node (host1) can fence host2 normally. Why fence fail when method=cycle?
3.What is the difference between onoff and cycle in fence ipmilan?

Contributor guide

No contributing guide indexed for this repository

Research direction

Start at the fence_ipmilan entry point and inspect the logged ipmitool chassis power status and chassis power cycle commands. Compare the method=cycle and onoff paths, including how the reported command failure becomes “Connection timed out”; done means explaining the behavior and identifying the appropriate handling or documentation change.

Written by the indexing model from the issue text.

Assessment

Tech stack
python
Domain
devops, infrastructure
Issue type
Bug
Difficulty
4/5
Estimated time
3-5 days
Activity status
Stale
Clarity
Needs clarification
Newbie friendliness
25/100

Get new issues in your inbox

A short digest of beginner-friendly GitHub issues.